DNA was extracted from a total of 84 marmosets consisting of fibroblast samples from WNPRC (n=61) and hair follicle samples from SNPRC (n=23). Among those 84 marmosets, 16 originated from the now defunct NEPRC and 18 originated from the Defence Science and Technology Laboratory, UK.
WGS library preparationWhole genome sequencing data was generated for 84 marmoset samples at BCM-HGSC using established library preparation and sequencing methods. Libraries were prepared using KAPA Hyper PCR-free library reagents (KK8505, KAPA Biosystems Inc.) on Beckman robotic workstations (Biomek FX and FXp models). Briefly, DNA (750 ng) was sheared into fragments of approximately 200-600 bp using the Covaris E220 system (96 well format, Covaris, Inc. Woburn, MA) followed by purification of the fragmented DNA using AMPure XP beads. A double size selection step was employed, with different ratios of AMPure XP beads, to select a narrow size band of sheared DNA molecules for library preparation. DNA end-repair and 3'-adenylation were then performed in the same reaction followed by ligation of the Illumina unique dual barcodes adapters (Cat# 20022370) to create PCR-Free libraries, and the library was run on the Fragment Analyzer (Advanced Analytical Technologies, Inc., Ames, Iowa) to assess library size and presence of remaining adapter dimers. This was followed by qPCR assay using KAPA Library Quantification Kit (KK4835) using their SYBR FAST qPCR Master Mix to estimate the size and quantification.
Illumina SBS SequencingThe Illumina WGS libraries were pooled and run with the S4 flow cells using NovaSeq SBS reagent kit v1.5 on the NovaSeq 6000 instruments according to the manufacture's procedure. Briefly, the pool of sequencing library was loaded onto the S4 flow cell around 250 pM using the XP 4-lane kit. Cluster generation and 2x150 cycles SBS sequencing were done on the NovaSeq instrument to generate 150 bp paired-end reads with on-instrument base calling. Sequence data were transferred off instruments for further processing, including mapping, using the HGSC workflow management system HgV (Mercury V, version.17.5).
Mapping and Variant CallingBWA-MEM (v0.7.15) was used to map all sequences to the Callithrix_jacchus_cj1700_1.1 (GCF_009663435.1) reference, which also included the mitochondria genome (NC_025586.1). To identify reads potentially originating from a single fragment of DNA and mark them in the BAM files, we used Picard MarkDuplicates (v2.6.0). Variants were then called using GATK (v4.2.2.0) following best practices and a joint called VCF file was generated. The hard filters suggested by the developers of GATK were applied to the SNVs and indels and all failing variants were removed. We then used GATK VariantAnnotator to annotate SNVs applying AlleleBalance. SNVs with an allelic balance for heterozygous calls (ABHet=ref/(ref+alt)) ABHet < 0.2 or ABHet > 0.8 were removed. Similar allele balance filtering was performed for indels using an in house script. Indels longer than 6 bp were removed. Ensembl Variant Effect Predictor (VEP) (v98) was used to annotate the SNVs in the VCF file based on NCBI RefSeq gene annotations. The average sequencing coverage used for SNV genotype calls in the samples was 34.21X.
Liftover to human hg38 assemblyIn order to lift over marmoset variants to orthologous human hg38 positions, we used the Picard (v2.18.14) LiftoverVcf tool with LIFTOVER_MIN_MATCH=0.95 and RECOVER_SWAPPED_REF_ALT=true, which means if a marmoset ALT allele is the REF allele in human then the REF and ALT alleles will be swapped, otherwise the SNV will be removed. Picard LiftoverVcf was performed reciprocally requiring that human sites must lift over back to original position on marmoset in order to be retained.